Error "A connection was successfully established with the server, but then an error occurred during the login process. (provider: Shared Memory Provider, error: 0 - No process is on the other end of the pipe"

Error "A connection was successfully established with the server, but then an error occurred during the login process. (provider: Shared Memory Provider, error: 0 - No process is on the other end of the pipe"


Solution:
This is login authenticate problem. Please check the following things:

  • In the SQL Server Properties, please check that "SQL Server and Windows Authentication Mode" is enabled, if not enable, please enable and restart the SQL Server.
     
  • Is Login have the permission to particular Database?
     
  • This might be a firewall issue as you mentioned it only happens when security agent installed. Please make sure you have properly configured security agent to allow Database Engine Services accesses.
     


Comments

Popular posts from this blog

IIS, There was an error when trying to connect. Do you want to retype your credentials and try again?

IIS 8 error on windows server 2012 insufficient permission There was an error when trying to connect. Do you want to retype your credentials and try again? Details: Filename: \?\C:Windows\system32\inetsrv\config\redirection.config Error: Cannot read configuration file due to insufficient permissions screenshot: Solution: Steps to short out this issue: go to C:\Windows\Microsoft.Net\Framework64\v2.0.50727\CONFIG\machine.config here you got the redirection tag like the below <configurationredirection enabled="true" password="[enc:IISCngProvider:X0ObCWwZ4+PrTHiFVPtzFeCcL8u5P6KUOYfo1/0QrgZWATA5pKWqHvD8nL2crNJKyyqr4z/rBdLPjdRcaLxAMMj4l+lvp5EXXKSXueolvyGa34F4QZfbBVCM6oVNcq3M368TOTVjJv4POVFQWvu0MDVlGgReglXB+Lw5BRI4Htw=:enc]" path="C:\Windows\System32\inetsrv\config\import\" username="Administrator"> </configurationredirection"></li"> you need to change this to <configurationRedirection /> Th...

Plesk - Upgrade the .net Framework to 4.7.2 OR 4.8

 Steps to Upgrade the .net Framework to 4.7.2 OR 4.8 1. First Download the .NET Framework from https://dotnet.microsoft.com/download/dotnet-framework   2. Install on the Server. 3. Login to the Plesk and go to "Tools & Settings" > "Server Components" and refresh the components using the refresh button 4. After update, it will reflect in "Web Script" section at the server component page. All done!!!